inquiry@elontherm.com    +86-571-81636790
enLanguage
Cont

Have any Questions?

+86-571-81636790

Aug 12, 2024

What Is The Difference Between A Tube Furnace And A Muffle Furnace?

Tube furnace and Muffle furnace are commonly used heating equipment, and are widely used in industry and element analysis. Although these two devices are used to heat the workpiece, but also have some different roles, so what are the differences between the tube furnace and the Muffle furnace, the next Xiaobian will bring you the relevant introduction.
The difference between a tube furnace and a Muffle furnace
1, the production is not the same: because the furnace diameter of the tube furnace is fixed, the production is relatively small; The size of the Muffle furnace can be adjusted, so the amount of testing or production is larger.
2, the calcination atmosphere is not the same: in the use of tubular furnace calcination, the workpiece can not be fully integrated with the air, it is easy to appear incomplete calcination; In the calcination process of the Muffle furnace, the workpiece can be fully fused with the air, so that it can be fully calcined.
Installation and use of Muffle furnace
1. After the arrival of the Muffle furnace equipment, check the equipment first to see whether the equipment accessories are complete, so as not to affect the use.
2, after checking that the equipment accessories are complete, place it on the flat ground, pay attention to the controller of the Muffle furnace to take shockproof measures, and can not be too close to the heat source.
3. When connecting the thermocouple with the Muffle furnace, it is necessary to confirm the positive and negative electrodes first to avoid the negative and positive electrode connection affecting the use of the equipment.
4, Muffle furnace needs to install a special power switch, so that it is more convenient to control the total power supply when in use.
5, when the Muffle furnace is used for the first time, it is necessary to check its operating instructions first, and then operate according to the steps on the instructions, such as first returning the temperature to zero, so that the later control will be more accurate.
6, check the wiring situation, after confirming that there is no error, the controller cover, you can start to work.
7. In order not to affect the service life of the Muffle furnace, it is recommended that the heating rate and cooling rate be 10℃/min when used.
8. After the Muffle furnace has been used for a period of time, there will be tiny cracks in the furnace, which is a normal phenomenon and will not affect its use, it can be ignored, or it can be repaired with alumina coating.
9, Muffle furnace is not recommended to enter corrosive gases, if you want to enter strong corrosive gases such as S, Na, etc., need to contact the manufacturer for special treatment of the furnace before access to such gases.

Send Inquiry